When effective powder containment is needed during bulk manipulation, the PowderSafe Bulk Handling enclosure is an economical and space-saving alternative to larger walk-in enclosures. With a unique drum access port incorporated into the base of the enclosure, the drum can be raised and sealed to the access port, effectively extending the enclosure’s containment area into the drum. Designed to provide a turbulence-free airflow environment, PowderSafe Bulk Handling enclosures move air in a horizontal pattern to maximize containment while minimizing sample loss and balance instability.
Features |
AirSafe automatic safety controller |
No ductwork required |
No installation required - plugs directly into a standard 110V or 220V electrical outlet |
Polypropylene construction for chemical resistance. The result: NO RUST |
Wide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate |
Integral vapor-proof fluorescent lighting |
Constant monitoring of fume hood face velocity with variable airflow control to user preset value |
Permanent backup HEPA filter |
Horizontal laminar airflow pattern |
Bulk container access port cover |
Lab event timer |
Benefits |
Filter safety lockout to ensure correct filter replacement |
Exhaust air is HEPA filtered, keeping any potential particulate from returning to the room |
Tested to UL 61010-1 and CSA C22.2 No. 61010-1 |
Brushless, sparkless blower is post-filter |
Deep base effectively contains accidental spills |
Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas |
Low airflow alarm warns the user both visually and audibly |
Real time monitoring of installed filtration bed |
HEPASafe technology allows safe HEPA filter change while enclosure is operational |
Options |
Sturdy stand with leveling feet |
ULPA filter |
Carbon filtration for liquid chemicals |
Contrasting base color |
Waste port for weighing vessels |
Hydraulic lift |
Gas phase bonded carbon filtration |
Product # | External | ||
---|---|---|---|
Width | Depth | Height | |
AC794BE | 48" | 36" | 54" |
AC795BE | 60" | 36" | 54" |
AC796BE | 72" | 36" | 54" |
Product # | Internal | ||
AC794BE | 47" | 29" | 35" |
AC795BE | 59" | 29" | 35" |
AC796BE | 71" | 29" | 35" |
Air enters in an even horizontal laminar fashion.
Contaminated air enters and particulate is removed via electrostatic pre-filtration and HEPA filtration.
Particulate free air moves upward where it enters the HEPASafe™ filtration area.
Particulate free air passes into the bonded carbon filtration bed to remove chemical fumes and vapors.
Clean air is recirculated into the room.