The AC600 Series ductless chemical workstation is an economical, operator protection product that protects the end user from toxic vapors, gases, fumes, and particulate. Smaller and more mobile than a standard ductless fume hood, AC600 Series ductless chemical workstations are the perfect solution for performing low-volume applications with known chemicals. These products come standard with the same advanced safety features and technology as larger AirClean® Systems ductless hoods: gas phase bonded carbon filtration, real-time gas detection, and constant airflow control and monitoring.
| Features |
| AirSafe automatic safety controller |
| Integral base with deep spill lip |
| No ductwork required |
| No installation required - plugs directly into a standard 110V or 220V electrical outlet |
| Clear polycarbonate shell for 360° visibility |
| Extremely quiet operation < 49dBA |
| Available in standard height or tall version |
| Constant monitoring of fume hood face velocity with variable airflow control to user preset value |
| Lab event timer |
| Gas phase bonded carbon filtration |
| Benefits |
| Filter safety lockout to ensure correct filter replacement |
| Shipped fully assembled |
| Electronic gas detection for real-time gas phase filter monitoring |
| Tested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1 |
| Brushless, sparkless blower is post-filter |
| Deep base effectively contains accidental spills |
| Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas |
| Low airflow alarm warns the user both visually and audibly |
| Real time monitoring of installed filtration bed |
| Options |
| Sturdy cart/trolley with locking casters for mobility |
| Access port for electrical cords |
| Fluorescent lighting optional on all 32" width workstations; standard on 48" workstations |
| ULPA filter |
| Polypropylene laboratory sinks |
| Product # | External | ||
|---|---|---|---|
| Width | Depth | Height | |
| AC632A | 32" | 25" | 30" |
| AC632TA | 32" | 25" | 40" |
| AC632TAS | 32" | 25" | 40" |
| AC648A | 48" | 25" | 31" |
| AC648TA | 48" | 25" | 41" |
| AC648TAS | 48" | 25" | 41" |
| Product # | Internal | ||
| AC632A | 31" | 23" | 19" |
| AC632TA | 31" | 23" | 26" |
| AC632TAS | 31" | 23" | 29" |
| AC648A | 47" | 23" | 19" |
| AC648TA | 47" | 23" | 26" |
| AC648TAS | 47" | 23" | 29" |
Room air flows away from the operator and enters the enclosure in a horizontal pattern.
Room air mixes with both lighter and heavier gases.
Contaminated air is directed through the filtration bed.
Clean air is recirculated into the room.