Endeavour ductless fume hoods provide the operator with user-friendly controls, superior construction materials and market-leading safety features needed for effective fume containment. Endeavour ductless fume hoods can be placed virtually anywhere, without the need to connect to building infrastructure, giving you the flexibility expected from modern laboratory equipment.
Features |
Integral base with deep spill lip |
No installation required - plugs directly into a standard 110V or 220V electrical outlet |
Wide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate |
AirZone baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, eliminating "dead spots" within the hood |
Structural thermally-fused polypropylene construction for superior chemical resistance and spill containment |
Constant monitoring of fume hood face velocity with variable airflow control to user preset value |
Built-in solid state gas detection |
Large capacity filtration bed to handle a wide variety of applications |
Touch-screen microprocessor control with variable airflow controller and constant filter monitoring |
ChemMinder™ chemical class confirmation - user notification of chemical/filtration compatibility |
Lab event timer |
Gas phase bonded carbon filtration |
Benefits |
Filter safety lockout to ensure correct filter replacement |
AirZone™ baffling to prevent fume hood roll and provide superior containment of gases and vapors |
Electronic gas detection for real-time gas phase filter monitoring |
Tested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1 |
Brushless, sparkless blower is post-filter |
Deep base effectively contains accidental spills |
Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas |
Low airflow alarm warns the user both visually and audibly |
Real time monitoring of installed filtration bed |
Options |
Deck-mounted fixtures |
Access port for electrical cords |
Vented and unvented polypropylene base cabinets |
Sturdy stand with leveling feet |
ULPA filter |
Custom access ports for routine equipment maintenance |
Polypropylene laboratory sinks |
Product # | External | ||
---|---|---|---|
Width | Depth | Height | |
ACPT4000 | 48" | 30" | 54" |
ACPT4036 | 48" | 36" | 54" |
ACPT6000 | 72" | 30" | 54" |
ACPT6036 | 72" | 36" | 54" |
Product # | Internal | ||
ACPT4000 | 47" | 26" | 35" |
ACPT4036 | 47" | 32" | 35" |
ACPT6000 | 71" | 26" | 35" |
ACPT6036 | 71" | 32" | 35" |
Room air flows away from the operator and enters the enclosure in a horizontal pattern.
Room air mixes with both lighter and heavier gases.
Mixed air is drawn into the AirZone™ baffling.
Contaminated air is directed through the filtration bed.
Clean air is recirculated into the room.