AirClean® Systems Type C PowderSafe ductless balance enclosures incorporate the airflow dynamics and HEPASafe™ features of the PowderSafe Type B with the user-friendly features and chemical fume containment capabilities of an AirClean Systems ductless fume hood. Thermally-fused polypropylene construction makes the PowderSafe Type C enclosure perfect for weighing powders or solvents.
Features |
AirSafe automatic safety controller |
No ductwork required |
No installation required - plugs directly into a standard 110V or 220V electrical outlet |
Polypropylene construction for chemical resistance. The result: NO RUST |
Integral vapor-proof fluorescent lighting |
Constant monitoring of fume hood face velocity with variable airflow control to user preset value |
Effectively weigh to 7 decimal places |
Permanent backup HEPA filter |
Horizontal laminar airflow pattern |
Lab event timer |
Gas phase bonded carbon filtration |
Benefits |
Filter safety lockout to ensure correct filter replacement |
Exhaust air is HEPA filtered, keeping any potential particulate from returning to the room |
Shipped fully assembled |
Electronic gas detection for real-time gas phase filter monitoring |
Tested to UL 61010-1 and CSA C22.2 No. 61010-1 |
Brushless, sparkless blower is post-filter |
Deep base effectively contains accidental spills |
Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas |
Low airflow alarm warns the user both visually and audibly |
ASHRAE 110 tested |
Real time monitoring of installed filtration bed |
HEPASafe technology allows safe HEPA filter change while enclosure is operational |
Options |
Sturdy stand with leveling feet |
ULPA filter |
Carbon filtration for liquid chemicals |
Contrasting base color |
Waste port for weighing vessels |
Polypropylene base cabinet |
Gas phase bonded carbon filtration |
Product # | External | ||
---|---|---|---|
Width | Depth | Height | |
AC760C | 36" | 30" | 44" |
AC765C | 36" | 30" | 54" |
AC770C | 48" | 30" | 44" |
AC775C | 48" | 30" | 54" |
AC780C | 72" | 30" | 44" |
AC785C | 72" | 30" | 54" |
Product # | Internal | ||
AC760C | 35" | 22" | 25" |
AC765C | 35" | 22" | 35" |
AC770C | 47" | 22" | 25" |
AC775C | 47" | 22" | 35" |
AC780C | 71" | 22" | 25" |
AC785C | 71" | 22" | 35" |
Air enters in an even horizontal laminar fashion.
Contaminated air enters and particulate is removed via electrostatic pre-filtration and HEPA filtration.
Particulate free air moves upward where it enters the HEPASafe™ filtration area.
Particulate free air passes into the bonded carbon filtration bed to remove chemical fumes and vapors.
Clean air is recirculated into the room.