Happy New Year! Our office will be closed on Thursday, January 1, 2026 and we will resume normal business hours on Friday, January 2, 2026. We are thankful for your continued support and look forward to working with you in the new year!
AirClean® Systems Type C PowderSafe ductless balance enclosures incorporate the airflow dynamics and HEPASafe™ features of the PowderSafe Type B with the user-friendly features and chemical fume containment capabilities of an AirClean Systems ductless fume hood. Thermally-fused polypropylene construction makes the PowderSafe Type C enclosure perfect for weighing powders or solvents.
| Features |
| AirSafe automatic safety controller |
| No ductwork required |
| No installation required - plugs directly into a standard 110V or 220V electrical outlet |
| Polypropylene construction for chemical resistance. The result: NO RUST |
| Constant monitoring of fume hood face velocity with variable airflow control to user preset value |
| Effectively weigh to 7 decimal places |
| Permanent backup HEPA filter |
| Horizontal laminar airflow pattern |
| Lab event timer |
| Gas phase bonded carbon filtration |
| Integrated LED Lighting |
| Benefits |
| Filter safety lockout to ensure correct filter replacement |
| Exhaust air is HEPA filtered, keeping any potential particulate from returning to the room |
| Shipped fully assembled |
| Electronic gas detection for real-time gas phase filter monitoring |
| Tested to UL 61010-1 and CSA C22.2 No. 61010-1 |
| Brushless, sparkless blower is post-filter |
| Deep base effectively contains accidental spills |
| Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas |
| Low airflow alarm warns the user both visually and audibly |
| ASHRAE 110 tested |
| Real time monitoring of installed filtration bed |
| HEPASafe technology allows safe HEPA filter change while enclosure is operational |
| Options |
| Sturdy stand with leveling feet |
| ULPA filter |
| Carbon filtration for liquid chemicals |
| Contrasting base color |
| Waste port for weighing vessels |
| Polypropylene base cabinet |
| Gas phase bonded carbon filtration |
| Product # | External | ||
|---|---|---|---|
| Width | Depth | Height | |
| AC760C | 36" | 30" | 44" |
| AC765C | 36" | 30" | 54" |
| AC770C | 48" | 30" | 44" |
| AC775C | 48" | 30" | 54" |
| AC780C | 72" | 30" | 44" |
| AC785C | 72" | 30" | 54" |
| Product # | Internal | ||
| AC760C | 35" | 22" | 25" |
| AC765C | 35" | 22" | 35" |
| AC770C | 47" | 22" | 25" |
| AC775C | 47" | 22" | 35" |
| AC780C | 71" | 22" | 25" |
| AC785C | 71" | 22" | 35" |
Air enters in an even horizontal laminar fashion.
Contaminated air enters and particulate is removed via electrostatic pre-filtration and HEPA filtration.
Particulate free air moves upward where it enters the HEPASafe™ filtration area.
Particulate free air passes into the bonded carbon filtration bed to remove chemical fumes and vapors.
Clean air is recirculated into the room.